Delta RMC151 User Manual

Page 532

Advertising
background image

RMC70/150 and RMCTools User Manual

*These registers are typically REAL data type (floating point), but in some cases may be

DINT or DWORD integers, such as variables declared as such.

Response Block
The Response Block is a block of 16 contiguous 32-bit input registers (cyclic read

registers). Registers 0-7 correspond to the Indirect Data Map registers 0 to 7 in the

RMC70. These registers are continuously sent from the RMC to the PLC or PC. Registers

8-15 are for explicit reads or writes.
The Response Block has the following structure:

Register
Number

Data
Type


Description

Note:

Register 0 supplies the reading and writing acknowledge for the

Command Block register 6.
Note:

Registers 0-7 are consistent. See explanation below.

0

Integer Indirect Data 0 - must be mapped to Axis

0 Status bits!

Bit

Bit Description

31

Command Acknowledge

30

Read/Write Acknowledge

0-29 Axis 0 Status Bits

1

Float*

Indirect Data 1

2

Float*

Indirect Data 2

3

Float*

Indirect Data 3

4

Float*

Indirect Data 4

5

Float*

Indirect Data 5

6

Float*

Indirect Data 6

7

Float*

Indirect Data 7

Note:

Register 8 supplies the reading and writing acknowledge for

registers 9-15.

8

Integer Read/Write Acknowledge Register

Bit Bit Description
30

Read/Write Acknowledge

Note:

The entire Command Register 8 is echoed

to this Read/Write Acknowledge Register.

Typically, bit 30 is the only bit used.

9

Float*

Explicit Read Data 0

10

Float*

Explicit Read Data 1

11

Float*

Explicit Read Data 2

12

Float*

Explicit Read Data 3

13

Float*

Explicit Read Data 4

512

Delta Computer Systems, Inc.

Advertising