Delta RMC151 User Manual

Page 1112

Advertising
background image

RMC70/150 and RMCTools User Manual

Major * 256 + Minor

F7:23

3631

D03630 REAL

%MD7.23

DINT

Required RMCTools Ver
Major * 256 + Minor (patch

ignored)

F7:24

3633

D03632 REAL

%MD7.24

DINT

Suggested RMCTools Ver
Major * 256 + Minor (patch

ignored)

F7:25

3635

D03634 REAL

%MD7.25

DINT

Loader Rev
Major * 256 + Minor

F7:26

3637

D03636 REAL

%MD7.26

DINT

Loader Year and Month
Year (4-digit) * 16 + Month

(1=Jan, 2=Feb, ...)

F7:27

3639

D03638 REAL

%MD7.27

DINT

Loader Day and Time
Date (1-31) * 2048 + Hour (0-

23) * 64 + Minute

F7:28

3641

D03640 REAL

%MD7.28

DINT

Loader Command
For sending certain commands

to the loader, such as restart

the RMC. See Loader

Command for more details.

F7:29

3643

D03642 REAL

%MD7.29

DINT

Reason in Loader
0: Not in Loader
1: Explicitly Requested by

Firmware (e.g. Firmware

Update)
2: Bad FW Image Checksum
3: Invalidate FW Image Header
4: CPU Module not supported

by FW Image
6: Watchdog Timeout
7: Boot of FW Image Failed
9: Force-to-Loader Jumper is

set

F7:30

3645

D03644 REAL

%MD7.30

DINT

Loader State
Only used when updating.

Confidential

F7:31

3647

D03646 REAL

%MD7.31

DINT

CPU Board Version
This indicates the actual CPU

board revision.
Bits 0-7: Mod Level (0=A,

1=B, etc.)
Bits 8-15: Minor Revision
Bits 16-23: Major Revision
Bits 24-31: Reserved

For example, 2.1E will be

0x00020104.

F7:32

3649

D03648 REAL

%MD7.32

DINT

Firmware Patch Number

1092

Delta Computer Systems, Inc.

Advertising