RMC70/150 and RMCTools User Manual

dropped because too many sets were received simultaneously.
The RMC70 allows up to 6 command sets (up to one command per axis in

each set) to be queued up before losing a command set. The RMC150 allows

up to 12 command sets (up to one command per axis in each set) to be

queued up before losing a command set.
One command set is processed (and thus, removed from the queue) per

control loop. It is possible, although unlikely, to overflow the queue by

simultaneously issuing commands from multiple sources for consecutive

control loops.

202 Flash update failed

An attempt to save the RMC settings to Flash failed. This indicates a failure

of the RMC hardware. Please contact Delta technical support if this occurs.

203 Unable to initialize the PROFIBUS sub-system

The PROFIBUS sub-system of the hardware could not be started. This

indicates a failure of the RMC hardware. Please contact Delta technical

support if this occurs.

204 Target Position went out of limits

The Target Position of an axis went out of limits. Notice that this does not

occur because the axis is commanded to go outside of limits, as that is

caught by Command Adjusted error 81, but it indicates that a move was

given a low deceleration ramp that caused it to move outside the limits.

205 Unsupported Flash command received

This is an internal error. Please contact Delta technical support if this occurs.

206 Save of IP Setting to Flash failed

The save to Flash failed.

207 Command overwritten within a Task step

A command was overwritten in a user program. Check to make sure the step

does not issue more than one command to an axis.

208 Drive disabled due to Watchdog timeout

This indicates an internal error occurred that caused the control outputs to

be disabled. Please contact Delta technical support if this occurs.

209 Commands overwritten in the PROFIBUS command area

Commands were left in the PROFIBUS command area when either the first

deferred command or a singular command was issued. All commands that

had been in the command area are discarded without further processing.

210 Command overwritten in the PROFIBUS command area

A command was issued over the top of a deferred command in the

PROFIBUS command area. The deferred command is discarded without

further processing.

211 PROFIBUS read/write length invalid

The length field in the PROFIBUS Enhanced Data Channel had an invalid

value.

212 No follow-up command after Adv. Gear Move command

No follow-up command was issued after the Advanced Gear Move command

completed. See the Advanced Gear Move (33) for details.

213 PROFIBUS command received but no axes were selected.

Commands must always be issued to an axis, even if they aren't specific to

any axis. Make sure to set the axis select bits.

214 Simulate Mode Model Invalid.