Delta RMC151 User Manual

Page 1197

Advertising
background image

11 Troubleshooting

239 Image Area: Invalid command received.

The value written to the Image Area Command register is not supported.

Verify the value written to this register.

240 Image Area: Image downloaded out of sequence.

The image was downloaded improperly. This can happen for the following

reasons:

The Current Index register, if written at the start of each write,

may have the wrong value.

The Image Data registers were not written to in sequential order.

That is, each consecutive write to the Image Data registers must

either start at the first Image Data register, or must continue

where the last write completed.

An individual write extended beyond the end of the Image Area file

(4096 total registers).

The total re-assembled downloaded image exceeds 65,536 registers.


To recover from this error, reset the download by writing a zero to the

Current Index register or by writing Reset Image Area (3) to the Image

Area Command register, and then resend the image starting at the

beginning.

241 Image Area: Image uploaded out of sequence

The image was uploaded improperly. This can happen for the following

reasons:

The Image Data registers were not read in sequential order. That

is, each consecutive read from the Image Data registers must

either start at the first Image Data register, or must continue

where the last read completed.

An individual read extended beyond the end of the Image Area file

(4096 total registers).

More than 65,536 total registers have been uploaded.


To recover from this error, write a zero to the Current Index register and

re-upload the image starting at the beginning.

242 Image Area: Invalid Current Index value written.

A non-zero value was written to the Current Index register in the Image

Area. This is only allowed when downloading an image. This register should

not be written to while uploading or at other times.

243 Image Area: Download not allowed in this state.

The Image Data registers cannot be written to while the Image Area is in

this state. Before downloading an image to the Image Area, you should

reset the image area by writing Reset Image Area (3) to the Image Area

Command register. This error can also occur if writes are made after an

Image Area: Image downloaded out of sequence error has occurred.

244 Image Area: Unable to build upload image.

This error will occur if the entire image in the controller is larger than the

maximum size of 65,536 registers and therefore could not be created.

245 Image Area: Unable to apply downloaded image.

The controller was unable to apply the downloaded image. The state of the

controller has not been changed. There are several reasons why the RMC

may be unable to apply a downloaded image. The reason will be listed in the