Delta RMC151 User Manual

Page 684

Advertising
background image

RMC70/150 and RMCTools User Manual

Part Number

The part number of the Resolver module is Rn, where n is the number of Resolver

modules.
For example, RMC150E-R1 is an RMC150E with one Resolver module. RMC150E-R3-Q1 is

an RMC150E with three Resolver modules and one Quadrature module.

Setting Up the Resolver Module

1. Wire the resolver according to the RMC150 Resolver Wiring topic.
2. Set the following parameters:

Resolver Resolution

Reference Amplitude

Reference Frequency

3. Scale the axis. Typically, resolvers will use Rotary Scaling. Notice that one revolution

of the resolver will always consist of 65,536 counts on the RMC, regardless of the

resolver resolution parameter.

Specifications

For general specifications on the RMC150, see the RMC150 Overview topic.

Resolver Interface

Axes Two per module

Reference Frequency 800 Hz to 5 kHz

Reference Output

Voltage

1.42 to 4.8V RMS

Reference Output

Current

28 mA max

Resolver Transformation

Ratio

(SIN

MAX

/Reference)

0.42 to 1.41

Resolver Input Voltage 2V RMS ±15%

Resolution 14 or 16 bits

Maximum Speed 14 bits: 3000 RPM

16 bits: 600 RPM

Maximum Acceleration 14 bits: 1200 RPS per second

16 bits: 60 RPS per second

Accuracy 4 Minutes + 1 LSB

Control Outputs

Range ±10 V @ 5 mA (2 kΩ or greater load)

(For current output, use the VC2124 accessory:±10 mA to

±200 mA in 10mA steps)

Tolerance At 10 V: +200 mV, -100 mV

At 0 V: ±50 mV

At -10 V: +100 mV, -200 mV

Resolution 14 bits

Output Isolation 500VAC

LEDS

Axis 0 LED
Axis LED applies to the Drive 0 output or feedback input 0 as described below:

664

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: