9 Register Reference

80: Resolver (RW)

F144+n:1 73731

+512 x n

E1_08194

+512 x n

DWORD %MD144+n.1 DWORD Read

Only

Slot n Module Rev
Major * 256 + Minor


Module UI/O
Slot n = 0-5
AB
DF1,
CSP

Address

Modbus

TCP,RTU

Address

FINS
Address

External
Data

Type

Internal
I
EC

Address

Internal

Data

Type

Access

Register Name

F144+n:0 73729

+512 x n

E1_08192

+512 x n

DINT

%MD144+n.0 DINT

Read Only Slot n

Module ID = 45 (comm

slot)

Module ID = 77 (sensor

slot)

F144+n:1 73731

+512 x n

E1_08194

+512 x n

DWORD %MD144+n.1 DWORD Read Only Slot n Module Rev

Major * 256 + Minor

F144+n:2 73733

+512 x n

E1_08196

+512 x n

DWORD %MD144+n.2 DWORD Read Only Board Revision

0x00MMmmLL, where MM

is major, mm is minor,

and LL is letter (00=A,

01=B, etc.)

F144+n:3 73735

+512 x n

E1_08198

+512 x n

DINT

%MD144+n.3 DINT

Read Only Serial Number

Last 6 digits of the serial

number (yyqnnn)

F144+n:4 73737

+512 x n

E1_08200

+512 x n

DWORD %MD144+n.4 DWORD Read Only FPGA Image Date/Time

Bits 20-31: Year (4-digit

year)
Bits 16-19: Month

(1=Jan, etc.)
Bits 11-15: Day (1..31)
Bits 6-10: Hour (0..23,

0=12am, 1=1am, etc.)
Bits 0-5: Minute (00-59)

F144+n:16 73739

+512 x n

E1_08202

+512 x n

DWORD %MD144+n.16 DWORD Read/Write Channel 0 Mode

Bits 0-3 - Channel

Mode
0 = Quadrature Axis

Input
1 = SSI Axis Input
2 = SSI Register Input
3 = SSI Output
Bit 4 - SSI

Master/Slave
[Applies only to SSI

Output and SSI Register

Input modes]
0 = Master - Clock is an

output