Delta RMC151 User Manual

Page 670

Advertising
background image

RMC70/150 and RMCTools User Manual

State

Description

Steady Off

PROGRAM Mode or no power

Steady Green

RUN Mode

Communication LEDs
These LEDS are located below the Controller LED on a white background. These LEDs do

not convey 10/100, FDX/HDX, or Collision information. The user will have to rely on their

switch's LEDs or the RMCTools Ethernet Statistics to view those Ethernet status items.

Link/Act LED
The Link/Act LED reflects the status of the physical Ethernet connection between the

RMC and the device on the other end of the Ethernet cable. If this LED is not on or is

not blinking when you expect it to be, see the Ethernet Link/Act LED topic for

troubleshooting information.
State

Description

Off

The Ethernet link is down

Flashing Green

The Ethernet link is up, with activity

Steady Green

The Ethernet link is up, no activity


Net LED
State

Description

Steady Off

No power, or no IP address configured.

Steady Red

Duplicate IP Address detected.

Flashing Red

IP address configured and in use, and a

controlling EtherNet/IP I/O connection has

timed out and not been re-established.

Flashing Green

IP address configured and in use, no

EtherNet/IP or PROFINET connections are

currently established, and there is no timed-out

controlling EtherNet/IP I/O connection.

Steady Green

IP address configured and in use, at least one

EtherNet/IP or PROFINET connection is

currently established, and there is no timed-out

controlling EtherNet/IP I/O connection.

Discrete I/O LEDs

State

Description

Off

No power or input/output is off.

On

Input/output is on.

Startup LED Test
When the RMC150 powers up, the LEDs listed below goes through these states, with a

250 msec delay between each step:

CPU LED

Run LED

Net LED

Green

Off

Off

Red

Off

Off

Green

Green

Off

Green

Red

Off

Green

Off

Green

650

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: