7 Hardware

Features

One 5V RS-422 Quadrature input

One high-speed registration input for registration or homing

Uses

Encoder Reference Input

Reference inputs are often used as gearing or camming masters. Reference inputs

cannot be used for direct control of the input axis.

Input for a Control Axis

The Q1 input can be used for the input of a control axis. The Control Output must be

from an axis module.

Specifications

Quadrature Interface

Inputs 5V differential (RS422) receiver, Quadrature A, B

Input Impedance 16 kΩ unterminated

249 Ω terminated (selectable by jumpers)

Max. Encoder Frequency 8,000,000 quadrature counts/second

Common Mode Input Range -10 V to +13.2 V

Absolute Max Voltage ±25 VDC. Applying greater than ±25 V will damage the receiver

chip and will require repair by Delta. Notice that the quadrature

input is not compatible with 24 V signals.

Daisy-Chaining Daisy-chain one encoder to a maximum of 32 Q1 modules

Reg Input

Input Characteristics 12-24 VDC, sinking or sourcing

Logic Polarity True High

Min Turn-On Voltage 5.75 V
Min Turn-On Current 1.25 mA

Max Turn-On Voltage 6.5 V
Max Turn-On Current 2.0 mA

Max Input Voltage 26.4 VDC
Max Input Current 2.6 mA at 24 V

Reg Input Response Time 40 µs

LEDs

Quad LED

This LED represents the input and control status for the axis. This bi-color (red/green)

LED has the following states:

State

Description

Steady

Off

No power or this input is not assigned to an axis.

Steady

Green

The axis is either in closed loop control or is a reference axis. The axis is

not halted.

Flashing

Green

The input is in open loop and the axis is not halted (not possible for

reference axes).

Flashing

A Closed Loop Halt or External Halt has occurred because an error bit is set

deltamotion.com

643