Delta RMC151 User Manual

Page 240

Advertising
background image

RMC70/150 and RMCTools User Manual

Using the Plot Template Editor

The Plot Template Editor has two main sections, General Settings and Individual Plot

Settings. After making any changes to the plot settings, click the Download button in

the Plot Template Editor toolbar to apply the changes to the RMC.
General Settings
The General Settings section is used to specify how the RMC plot memory will be divided

between the plots in the plot set. The RMC has a fixed amount of memory dedicated to

plots. Therefore, if you increase the Number of Plots or the Data Sets per Plot, the

maximum number of samples per plot will decrease.

Plot Set Name

The name of the plot set. This can be used to provide a descriptive name for user

reference.

Number of Plots

Specify how many plots you want in the plot set.

Data Sets per Plot

Specifies the maximum number of data plots in each plot.

Individual Plot Settings
The Individual Plot Settings section is used to specify the settings for each plot in the plot

set. For any plot, the following items can be set:

Name

The name of the plot. This can be used to provide a descriptive name for user

reference.

Plot Duration

Specifies the plot length in seconds. If the plot duration is too long for the available

plot memory, an error bubble will appear.

Sample Interval

Specifies the time between each sample. A smaller value will result in finer detail on

the plot. Because the memory for a plot is limited, a larger Sample Interval will allow

for a longer Plot Duration. The Sample Interval cannot be smaller than the loop time

of the controller.

Default or Custom

Each individual plot can be set as either a Default or Custom plot, as described

below.

Default and Custom Plots

Default Plots
Default plots are managed by RMCTools. This option makes managing plots easy and is

recommended for most users. The user can choose the axis to plot, and can change the

Plot Duration and Sample Interval. Changing other settings requires choosing Custom

Plot.
RMCTools will automatically determine which registers should be plotted and how they

are displayed, based on the axis type. For example, if Axis 1 is a position-force axis, and

a plot is set to be a default plot for Axis 1, the plot will automatically be set to include the

Target and Actual Position, Velocity, and Force, Control Output, Status bits, and Mean

Squared Error for Position and Force.
To view which items are included in the plot, click What's in this Plot?
Custom Plots
Custom plots can be fully configured by the user. For more details, see Using Custom

Plots.

Plot Template Sets