Delta RMC151 User Manual

Page 1104

Advertising
background image

RMC70/150 and RMCTools User Manual

0-3, -1 = none

F39:4

19977

D19976 REAL

%MD39.4 REAL

Read/Write Plot Trigger Position

%, 0-100, -1 =

auto rearm

F39:5

19979

D19978 REAL

%MD39.5 UDINT Read/Write Plot Trigger Type

0-

7

Trigger Type
(0=none,

1=motion

command)

8-

23

Depends on

trigger type
Motion

Commands:
8-

11

Axis 0-3 bits,

if all zero,

then use

Axis Owner

12-

23

Reserved

F39:6

19981

D19980 REAL

%MD39.6

-

-

Reserved

F39:7

19983

D19982 REAL

%MD39.7

-

-

Reserved

F39:8

19985

D19984 REAL

%MD39.8 REAL

Read Only Plot ID

F39:9

19987

D19986 REAL

%MD39.9 REAL

Read Only Plot State

0 = not triggered, 1

= capturing, 2 =

complete

F39:10

19989

D19988 REAL

%MD39.10 DINT

Read Only Plot Captured

Samples
Number of plot

samples captured.

Only applies for Plot

State > 0.

F39:11

19991

D19990 REAL

%MD39.11 DINT

Read Only Plot Sample 0 Time

Time that first plot

sample was

captured. In control

loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

F39:12

19993

D19992 REAL

%MD39.12 DINT

Read Only Plot Trigger Time

Time that plot

trigger occurred. In

control loops since

controller startup

(low 24 bits). Only

applies for Plot

State > 0.

1084