Delta RMC151 User Manual

Page 854

Advertising
background image

RMC70/150 and RMCTools User Manual

See the Commands Overview topic for basic command information and how to issue

commands from PLCs, HMIs, etc.

Command Parameters

# Parameter Description

Range

1 I/O Point

any valid discrete

output

Description

This command turns off the specified discrete output. To use this command, you must

have defined a discrete I/O point to be an output using the Discrete I/O Configuration

dialog.
For details on settings multiple outputs simultaneously, see the Using Discrete I/O topic.
This command is an immediate command. Each step in a user program can have a

maximum of one non-immediate command per axis. There is no limit to the number of

immediate commands in a single step of a user program.

I/O Point

When issuing this command from RMCTools, the I/O Point is the tag name of the

discrete output, if it has a name, or the address of the discrete output.
Use the I/O Monitor to find the address or tag name of a particular I/O point, or to assign

a tag name to an I/O point. The address number appears in the icon of each discrete I/O

point in the I/O monitor.
I/O Point from a Host Controller
When issuing this command from a host controller, such as a PLC or HMI, the I/O Point

must be specified in integer format. The table below describes how to determine the

integer value of a discrete output.

RMC70

RMC150

Integer Number of a Discrete

Output

Integer Number = address number

The I/O Monitor also displays the

integer number of each I/O point.

Examples
The integer number for output

%QX2 is 2.

The integer number for output

%QX13 is 13.

Integer Number of a Discrete Output

Integer Number = (32 x slot#) + I/O#

The slot numbering starts with 0 for the left-most

module in the RMC150.
The I/O Monitor also displays the slot number and

I/O number of each I/O point. For example, the

I/O point 4 in slot 3 is displayed as 3.4.

Examples
The integer number for output 7 in slot 0 is:
(32 x 0) + 7 = 7

The integer number for output 1 in slot 1 (the CPU

slot) is:
(32 x 1) + 7 = 39

The integer number for output 3 in slot 5 is:
(32 x 5) + 3 = 163

834

Delta Computer Systems, Inc.

Advertising