9 Register Reference

Range: Same (0), Opposite (1), Bidirectional (2)

Default Value: Same (0)

Description

This register defines the orientation of the pressure/force relative to the orientation of the

position or velocity when in closed-loop control, or of the Control Output when in open-

loop control. It is important that this parameter is set correctly so that the Control Output

will be the correct polarity.
For Closed-Loop Control

Orientation Description
Same

The pressure/force increases as the position units increase.

Opposite

The pressure/force decreases as the position units increase.

For Open-Loop Control

Orientation Description
Same

The pressure/force increases with positive Control Output.

Opposite

The pressure/force decreases with positive Control Output.

Changing this Parameter
Because this parameter affects motion, the axis must be disabled or in Direct Output

before writing to this parameter. The Enabled and Direct Output Status Bits indicate these

states of the axis. When changing this parameter from RMCTools, the software will

automatically do this for you. This may cause a halt on the axis, which is expected.

Format Details

The Pressure/Force Orientation is selected with bits 5-6. These bits correspond to the

Pressure/Force Orientation as shown in the following table:

Bit 6 Bit 5 Value Pressure/Force Orientation

0

0

0

Same

0

1

1

Opposite


See the Primary Control Register and Secondary Control Register topics for details about

the register containing these bits.

9.2.2.5.9. Secondary Control Configuration Register

Type: Axis Parameter Register

RMC70 Address: %MDn.80, where n = 12 + the axis number

RMC150 Address: %MDn.80, where n = 24 + the axis number

System Tag: _Axis[0].SecControlBits, where n is the axis number

How to Find: See individual parameters below

Data Type: DWORD - see below

Description

The Control Configuration register contains the bit-addressable control configuration

parameters. This topic lists the bit address for each parameter. Each parameter is

accessible in RMCTools via the Axis Parameter Editor. For details on each parameter, see

the respective links.