Delta RMC151 User Manual

Page 294

Advertising
background image

RMC70/150 and RMCTools User Manual

Download All to Controller: Downloads all the parameters from the project to the

currently selected controller. This will overwrite the controller values.
Upload All from Controller:
Uploads all the parameters from the currently

selected controller to the project. This will overwrite the project values.
Save Communication Log:
Saves the log of RMCTools communications with the

RMC. This is only useful when requested by Delta technical support.
RUN Mode: Puts the controller in RUN Mode.
PROGRAM Mode: Puts the controller in PROGRAM Mode.
Enable Controller:
Issues an Enable Controller (7) command.
Fault Controller:
Issues a Fault Controller (8) command.
Clear All Faults: Issues a Clear Faults (4) command to every axis.
Update Flash: Updates the Flash memory.
View/Change Modules:
Opens the View/Change Controller Hardware dialog.
View/Change Axis Definitions: Opens the Axis Definitions dialog.
Reset Controller to Defaults: Resets the controller to its default settings.
View Communication Statistics: Opens the Communication Statistics window.


Programming

Download Programs to Controller: Downloads all the contents of the

Programming folder to the controller.
Upload Programs from Controller:
Uploads all of the contents of the

Programming folder from the controller.
Compare to Controller:
Compares the Programming node of the project with
that of the RMC. Yellow warning triangles and a yellow background will mark the

items where differences exist. To resolve the differences, download or upload the

Programming node.
New User Program:
Creates a new User Program.
Export User Program:
Exports a User Program.
Import User Program:
Imports a User Program.
Verify Programs:
Verifyies the programs (all the contents of the Programming

folder).
Lock Programming: Locks the user programs so changes cannot be made. See

Programming Security for details.
Unlock Programming: Unlocks the user programs so changes can be made. See

Programming Security for details.
Browse Labels: Displays a list of all the Labels in the user programs and their

locations.


Plots

Open Plot Manager: Opens the Plot Manager.
Edit Plot Templates:
Opens the Plot Template Editor.
Download Plot Templates to Controller:
Downloads the Plot Templates to the

controller.
Upload Plot Templates from Controller:
Uploads the Plot Templates from the

controller.
Compare to Controller:
Compares the Plots node of the project with that of the
RMC. Yellow warning triangles and a yellow background will mark the items

where differences exist. To resolve the differences, download or upload the Plots

node.
Save Plots:
Save any of the plots listed on the History tab.

274

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: