Ma axis module, 70 ma module – Delta RMC151 User Manual

Page 652

Advertising
background image

RMC70/150 and RMCTools User Manual

Green
Flashing

Green

The Fault input is inactive, and the Enable output is inactive.

Steady

Red

The Fault input is active. Notice that it is not possible to tell if the Enable

output is active or inactive.

7.2.4.3. MA Axis Module

The MA module is one of the axis modules available for the RMC70. It interfaces to

Magnetostrictive Start/Stop and PWM and SSI transducers and has 1 analog servo output per

axis. The MA module is available with either 1 or 2 axes, called the MA1 and the MA2.
For details on Magnetostrictive and SSI, see the Magnetostrictive Displacement Transducers

and Synchronous Serial Interface topics.
Note:

Linear magnetostrictive transducers with SSI output must be of the synchronized type. See

the SSI Fundamentals topic for details.

Important!

When using SSI, the MA module requires RS-422 (5 V differential) SSI inputs. It does not

support single-ended SSI inputs or higher voltage inputs.

Features

One MDT or SSI input per axis - each axis individually selectable

One ±10 V, 16-bit control output per axis

Current output up to ±200mA with VC2124 converter option

Can be used for controlling position. Can also be used for dual-loop control such as

position-pressure when used in conjunction with the AP2 module.

SSI can be used for rotary axes.

Part Number

The part numbers of the MA modules are MA1 and MA2 for the 1-axis and 2-axis

versions, respectively.
For example, RMC75E-MA1 is an RMC75E with a MA1 module.

Supported Transducers

Many different versions of MDT and SSI transducers exist, and the RMC70 MA axis

module supports a very wide variety of them. The following tables summarize the major

transducer options supported by the MA module:

MDT Options

Value

Types

Start/Stop (S/S)
Pulse-Width-Modulated

(PWM)

Count Range

32 bits

Wiring

Differential, 5 V, RS-422

Interrogation

Modes

External. Notice that

internal interrogation is not

supported.

MDT Count

240 MHz

SSI

Options

Value

Data Bits

8 to 32

SSI Format

Binary or Gray

Code

SSI Errors

None, all zeros, all

ones, or bit 21

Clock Rates

150, 250, and 375

kHz

632