Delta RMC151 User Manual

Page 574

Advertising
background image

RMC70/150 and RMCTools User Manual

such as the Variable Table or Command Area, you need not set up the Indirect Data

Map for the Incoming Data.

Example

If you have a 4-axis controller, you may wish to set up the Outgoing Data at the

beginning of the Indirect Data Map to include the Actual Position and the Status

Bits for each axis, in addition to information on Task 0, which perhaps runs your

user programs.

You may also wish to set the Incoming Data, starting at item 12 in the Indirect

Data Map, to go to 5 variables and some of the Axis 0 command registers. You

could then set up the Indirect Data Map like this:

3. Set the Cyclic I/O Data Locations in the RMC

In the Project pane, expand the Modules folder, double-click the CPU module, and

choose EtherNet/IP.

In the Outgoing Cyclic I/O Data section, enter the starting location for the Outgoing

Cyclic I/O Data. In our example, verify that the location is the Indirect Data Map Entry

0 Value.

In the Incoming Cyclic I/O Data section, enter the starting address for the

Incoming Cyclic I/O Data. Click the Browse button and browse to the desired RMC

location for the outgoing data. This should be a location in the Indirect Data Map,

554

Delta Computer Systems, Inc.

Advertising
This manual is related to the following products: