Enabled, E direct, Output – Delta RMC151 User Manual

Page 867: External halt, Halted, Direct output, Pressure/force control, E at, Pressure/force, Direct output status bit

Advertising
background image

9 Register Reference

1

1

Ramping

Control

Output

toward 0 V

Decelerating Decelerating

(toward 0

velocity)

Decelerating

in Closed

Loop

Decelerating

or Ramping

Down the

Control

Output

11 TGStateB

Primary Target Generator State B

See the Target Generator State A bit for a description of how these bits work. Specific

details on the Target Generator status bit are also included in the help topics for each

motion command.

12 DirectOut

Direct Output

When this bit is set, the axis in a Direct Output state. The axis is in open loop control

ignores all error bits, and the Auto Stops have no effect.
The Direct Output (9) command, and the Direct Output Halt will turn on this bit. If the

axis is disabled with the Enable/Disable Axis (97) command, this bit will turn on. If th

axis is enabled, any motion command (except Direct Output (9)) will turn off this bit.
Certain parameters that affect motion require the Direct Output Status bit to be on

when changing their values.

13 Enabled

Enabled

This bit is set when the Enable Controller (7) or Enable/Disable Axis (97) command is

issued to the axis. Motion commands are not allowed on the axis if this bit is not set

14 ExtHalt

External Halt

This bit is set when External Halt has occurred. An External Halt can only be triggered

by an Auto Stop.

15 Halted

Halted

This bit is set when one of the following halts occurs: Open Loop Halt, Open Loop Hal

with Disable Drive, or Closed Loop Halt.
These halts can then be triggered via Auto Stops or via explicit commands - see each

halt topic for details.

16 PFControl

Pressure/Force Control

This bit is set when the axis is in closed-loop pressure or force control.
This bit will not be set for pressure/force limit; see the Pressure/Force Limit Enabled

and Pressure/Force Limited bits below.

17 PFLimitEnabled

Pressure/Force Limit Enabled

This bit is set when Pressure/Force Limit mode is enabled on the axis. When this bit i

set, pressure or force will be limited to the Target Pressure/Force. Pressure/Force Lim

mode can only be enabled or disabled with the Set Pressure/Force Limit Mode (40)

command.
This bit does not indicate whether pressure/force is being limited. To determine

whether pressure or force is being limited, see the Pressure/Force Limited bit.

18 PFLimited

Pressure/Force Limited

This bit is set when the pressure/force is currently being limited. That is, the position

or velocity control is actually being affected in order to limit the pressure/force. This b

can only be on if the Pressure/Force Limit Enabled bit is on. See the Pressure Limit

topic for details on pressure control.
This bit will not be set in pressure/force control; see the Pressure/Force Control bit

above.

19 AtPF

At Pressure/Force

This bit indicates that the Actual Pressure/Force has reached the Command

Pressure/Force.

deltamotion.com