8 Command Reference

Command Parameters

# Parameter Description

Range

1 Stop Location

Next Cycle (0)

Middle (1)

Pos Peak (2)

Neg Peak (3)

Next Peak (4)

a valid integer as

described

Description

This command stops a pressure or force sine move at a prescribed location. For stopping

a position sine move, see the Sine Stop (73) command.
The sine move will stop at the next occurrence of the specified Stop Location. The Stop

Location can be any of the following:

Next Cycle

The sine move will stop at the end of the current cycle. The location of the end of each

cycle is defined by the Sine Start (Prs/Frc) (76) command. Stopping the sine move

with the Next Cycle option will ensure that the sine move stops in the same location

that it started. For example, if it started at a positive peak, this command will stop it

at the next positive peak.

If the stop location is the middle, and the axis is currently on the quadrant after a

peak and before the midpoint, then the axis will not stop on that first middle point

because it could lead to extreme pressure or force rates. Instead, the axis will

continue another full cycle and then stop at the middle point.
If the stop location is the middle, the target generator will perform the stop by

ramping the frequency down to zero over the last quarter-cycle. Due to this, any

attempt to ramp the frequency with the Change Target Parameter (Prs/Frc) (81)

command during this portion of the move will be ignored.

Middle

The sine move will stop at the first middle point. However, if the axis is currently on

the quadrant after a peak and before the midpoint, then the axis will not stop on that

first middle point because it could lead to extreme pressure or force rates. Instead,

the axis will continue a half-cycle after the first middle point and stop at the next

middle point.

When the Stop Location is set to Middle, the target generator performs the stop

by ramping the frequency down to zero over the last quarter-cycle. Due to this, any

attempt to ramp the frequency with the Change Target Parameter (Prs/Frc) (81)

command during this portion of the move will be ignored.

Pos Peak

The sine move will stop at the next positive peak.

Neg Peak

The sine move will stop at the next positive peak.

Next Peak

The sine move will stop at the next peak, whether it is negative or positive.

Status Bits

At Pressure or Force Bit
After the target pressure or force stops, and the Actual Pressure or Force is within the At

Pressure/Force Tolerance window, the At Pressure/Force Status bit will be set. This bit

indicates that the move is complete and the axis is at pressure or force.