Delta RMC151 User Manual

Page 679

Advertising
background image

7 Hardware

transducers. Finally, many SSI devices offer higher precision; for example, MDTs with SSI

output are available with resolutions to 2µm.
Note: Linear MDTs with SSI output should be of the synchronized type. Non-synchronized is

not well-suited for motion control.

See the SSI Fundamentals topic for details on the SSI standard.

Features

Two axes of SSI feedback per module

Supports SSI devices with Binary or Gray Code data from 8 to 31 bits in length

Differential RS-422 SSI interface

Two isolated, ±10 V, 12-bit control outputs per module

Current output up to ±200 mA with VC2124 converter option

Part Number

The part number of the SSI module is Sn, where n is the number of SSI modules.
For example, RMC150E-S1 is an RMC150E with one SSI module. RMC150E-S3-Q1 is an

RMC150E with three SSI modules and one Quadrature module.

Setting Up the SSI Module

To set up axes with SSI feedback, read the following topics:
SSI Wiring
SSI Scaling
The following parameters must be also set for axes with SSI feedback:

SSI Data Bits

SSI Format

The following advanced parameters can be optionally set for axes with SSI feedback:

SSI Clock Rate

Wire Break Detection

SSI Overflow Mode

SSI Home Source

Specifications

For general specifications on the RMC150, see the RMC150 Overview topic.

SSI Interface

Inputs Two RS-422 differential (does not support single-ended)

Clock Outputs Two RS-422 differential (does not support single-ended)

Clock Frequency user-selectable 230 kHz, 921 kHz

Input Impedance Data + Input: 140 Ω

Data - Input: 150 Ω

Required Cable Type Twisted pair, shielded

Maximum Cable Length Transducer Dependent, approx. 300-600 ft. See the SSI Clock Rate

topic for details.

ESD Protection 15 kV

Resolution Transducer dependent

Count Encoding Binary or Gray Code

deltamotion.com

659

Advertising
This manual is related to the following products: