Examples of circuit failover in groups – Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual

Page 1295

Advertising
background image

Brocade Network Advisor SAN + IP User Manual

1223

53-1003155-01

FCIP trunking

27

Examples of circuit failover in groups

Tables

Table 116

through

Table 118

provide examples of how failover occurs on circuits with

different bandwidths configured in failover groups.

Table 116

illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All

data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:

If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.

If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.

If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.

Table 117

illustrates circuit failover in a tunnel with one failover group containing three circuits, In

this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.

Table 118

illustrates circuit failover in a tunnel with circuits in failover groups and circuits that are

not part of failover groups. In this configuration, all data is initially load balanced over circuit.1,
circuit 2, and circuit 3 (when they are all active). The following occurs during circuit failover:

If circuit1 fails, circuit 4 becomes active and data is load balanced over circuit 2, circuit 3, and
circuit 4.

Reason: Circuit 1 fails over to circuit 4 (both are in failover group 1) and circuit 3 is active with
500Mb bandwidth.

If circuit 2 fails, data is load balanced over circuit 1 and circuit 3, and no other circuit becomes
active.

Reason: Circuit 1 and 3 are the only active circuits since circuit 4 and 5 only become active
when circuits 3 or 1 fail.

TABLE 116

Tunnel with two failover groups with two circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

500Mb

If active, yes.

Circuit 2
Metric 0

2

1000Mb

If active, yes.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 4
Metric 1

2

1000Mb

Only when circuit 2
fails.

TABLE 117

Tunnel with one failover groups with three circuits

Circuits in tunnel

Failover group ID

Circuit bandwidth

In use for tunnel data

Circuit 1
Metric 0

1

1000Mb

If active, yes.

Circuit 2
Metric 1

1

500Mb

Only when circuit 1
fails.

Circuit 3
Metric 1

1

500Mb

Only when circuit 1
fails.

Advertising