Master Log and Switch Console troubleshooting

H

Master Log and Switch Console troubleshooting

The following section states a possible issue and the recommended solution for switch console
errors.

Names troubleshooting

The following section states a possible issue and the recommended solution for names errors.

Problem

Resolution

Too many login and log messages received on
switch console and and Master Log due to lazy
polling.

NOTE: This setting cannot be disabled for DCB switches.
To disable lazy polling, complete the following steps.
1

Select Discover > IP Products.
The Discover Setup - IP dialog box displays.

2

Click the Global Settings tab.

3

Click the Preferences tab.

4

Clear the Enable lazy polling check box.

5

Click Apply to save your work.

6

Click Close to close the Discover Setup - IP dialog box.

7

Click Yes on the confirmation message.

Problem

Resolution

Duplicate name error.

If you configured the Management application to only allow unique names and you try to
use a name that already exists in the fabric. You can enter a different name for the device
or search for the duplicate name using one of the following procedures:

“Searching for a device by name”

on page 185 in the Configure Names dialog box

“Searching for a device by WWN”

on page 186 in the Configure Names dialog box

“Searching for a device”

on page 493