Discovery troubleshooting, Element manager troubleshooting, Fabric tracking troubleshooting – Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual

Page 2314: Discovery troubleshooting 2, Element manager troubleshooting 2, Fabric tracking troubleshooting 2

Advertising
background image

2242

Brocade Network Advisor SAN + IP User Manual

53-1003155-01

Discovery troubleshooting

H

Discovery troubleshooting

The following section states a possible issue and the recommended solution for discovery errors.

Element Manager troubleshooting

The following section states a possible issue and the recommended solution for Element Manager
errors.

Fabric tracking troubleshooting

The following section states a possible issue and the recommended solution for fabric tracking
errors.

Problem

Resolution

After upgrading to Management application
12.x from 11.x, unable to discover Fabric OS
devices. Error "4002" displays when trying to
discover Fabric OS devices.

The Management application 12.x uses Java 1.7, which disables the use of certificates
with "weak authentication". You must update your Java certificates to resolve the issue.

Problem

Resolution

Unable to launch Element Manager from the
Management application.

To launch Element Manager from the Management application, your local system's
browser must run the Java Web Start application. To turn on Java content in the browser,
complete the following steps.
1

Launch Java Control Panel.
For Windows: Refer to

http://java.com/en/download/help/win_controlpanel.xml

.

For Linux: Follow the steps listed.
a

Open the Terminal window.

b

Go to the Java installation directory: cd /java/jre1.7.0_45/bin (change the
name of the directory to where you have installed Java).

c

Type ./ControlPanel to open the Java Control Panel.

2

In the Java Control Panel, click the Security tab.

3

Select the Enable Java content in the browser check box.

4

Click Apply.
When the Windows User Account Control (UAC) dialog box displays, allow permissions
to make the changes.

5

Click OK in the Java Plug-in confirmation window.

6

Launch Element Manager.

Problem

Resolution

If a switch is replaced by another switch having
the same IP address but a different node WWN
while fabric tracking is on, the Management
application does not update the Product List,
Connectivity Map, or switch properties with the
new node WWN.

Choose from one of the following options:

Turn fabric tracking off while the switch is replaced. This causes the old switch to be
removed and the new switch added.

After the switch is replaced, remove and re-add the fabric in the Discover Setup
dialog box.

Advertising