Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual

Page 1708

Advertising
background image

1636

Brocade Network Advisor SAN + IP User Manual

53-1003155-01

Bottleneck detection

43

NOTE

It is recommended that you enable bottleneck detection on every switch in the fabric.

When you enable bottleneck detection, you also determine whether alerts are to be sent when the
bottleneck conditions at a port exceed a specified threshold. The alert parameters include whether
alerts are sent and the threshold, time, and quiet time options. These alert parameters apply to all
ports in the switch, unless you override them later.

After you enable bottleneck detection, you can change the alert parameters on all eligible ports,
switches, and fabrics.

NOTE

The best practice is to enable alerts and use the default values:

Congestion

80%

Latency

10%

Window

300 seconds

Quiet Time

300 seconds

Time threshold

0.8

Severity threshold

50

If you change the Window value, you should use a setting that is 300 seconds or higher.

If you change the alert parameters for a port, you can later cancel these settings and inherit the
settings from the switch. Refer to

“Inheriting alert parameters from a switch”

on page 1638 for

instructions.

Use the following steps to enable bottleneck alerts and configure alert parameters.

1. Select Monitor > Performance > Bottlenecks.

The Bottlenecks dialog box displays, as shown in

Figure 734

on page 1636.

FIGURE 734

Bottlenecks dialog box

2. Select Enable if it is not already selected.

3. Select the Congestion Alerts check box to enable alerts for congestion bottlenecks. Clear this

check box to disable alerts. If you enabled alerts, enter threshold values between 1 and 100,
or use the default value for triggering a congestion alert.

Advertising