Brocade Network Advisor SAN + IP User Manual v12.3.0 User Manual

Page 1596

Advertising
background image

1524

Brocade Network Advisor SAN + IP User Manual

53-1003155-01

802.1ag Connectivity Fault Management

37

NOTE

You cannot configure an 802.1ag CFM on a maintenance end point (MEP) configured with dual
tagged VLANs.

To add a MEP to an existing maintenance association, complete the following steps.

1. Click 802.1ag CFM.

The Configure 802.1ag CFM dialog box displays.

2. Select the maintenance association you want to edit in the Maintenance Association Details

table.

3. Click Edit.

The Edit Maintenance Association dialog box displays.

4. In the Available Maintenance End Points area, select a product from the Product list .

The list contains all products that are part of the VPLS.

5. Select a VLAN ID from the VLAN ID list.

The list contains all VLAN IDs in the VPLS.

6. Select a port from the Port list.

The list contains all VPLS end-points for the selected VLAN ID.

7. Enter a unique identifier for the end-point in the End Point ID field.

Valid values include 1 through 8191.

8. Select the MEP direction from the Direction list.

Options include:

Up — Select to set the MEP direction away from the monitored VLAN.

Down — Select to set the MEP direction towards the monitored VLAN.

9. Click the right arrow button to move the defined MEP to the Selected Maintenance End Points

table.

The Selected Maintenance End Points table lists the configured MEPs. Repeat step 4 through
step 10 for each MEP you want to add.

Advertising