Table 210

describes the SFP and POM fields of the Adapters Faulty SFP Report.

TABLE 210

Adapters Faulty SFP report fields and components

Field/Component

Description

SFP Supported

Whether the SFP is supported or not.

Connector Type

The type of port connector; for example, LC. SC, or Cu (copper cable).

Transceiver

The type of transceiver; for example, SFP or SFP+.

Media

The type of media for the transceiver; for example, single mode.

Speed

The port speed.

Extended ID

The identifier for the extended link.

Encoding

Displays how the extended link is encoded, for example, 8B10B.

Baud Rate

The transmission rate, roughly equivalent to the number of bits per second.

Length 9U1

The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).

Length 9U2

The length of the single-mode fiber-optic cable, used in situations where gigabit
performance is not required (for distances greater than 100 meters).

Length 50u

The length of the 50u fiber-optic cable (for distances greater than 10 meters).

Length 62.5u

The length of the 62.5u fiber-optic cable (for distances greater than 10 meters).

Length Cu

The length of the copper cable (for distances greater than 1 meter, where optimum
performance is required).

Vendor Name

The vendor of the extended link.

Vendor OUI

The vendor’s organizational unique identifier (OUI).

Vendor Part

The part number of the extended link.

Revision

The revision level of the extended link.

Wavelength

The wavelength translation, which enables longer reach through lower attenuation.

Options

Displays details about the transceiver; for example, the type of port connector, type of
transceiver, and enable/disable status.

BR Max

The upper bit rate limit at which the SFP transceiver meets its specifications.

BR Min

The lower bit rate limit at which the SFP transceiver meets it specifications.

Serial #

The serial number of the SFP transceiver.

Date Code

The date the SFP was manufactured transceiver.

Temperature (c)

The port temperature, measured in Celsius.

Bias Current (mA)

The low-level DC current (the Bias Current), measured in mA.

Tx Power (mW)

The transmitted power, measured in mW.

Rx Power (mW)

The received power, measured in mW.

Voltage (V)

The voltage; for example, 1.8V, 3.3V, or 5.0V.

Alarm/Warning

Indicates whether an alarm has been triggered.