DeviceLogix 9-27

1503-UM054C-EN-P – June 2013

Figure 9.16 – Input Forced Indication



Forcing Outputs

The following list describes the output force options.

Table 9.J – Output Forcing

Ouput Force Option

Description

Force On

Forces the input ON.

Force Off

Forces the input OFF.

Remove Force

Returns control of the input to the hardware device and

turns the instruction color back to white.

Clear Fault

When a device supports latching of faults, this selection

clears a hardware output fault indication (for example, off-

wire or short circuit).


Figure 9.17 shows the result of placing a force on an output. When

force, an output element turns yellow with a red triangle indicator

and the status value reflects the force state chosen.

Figure 9.17 – Output Force Indication


Dual Function Inputs

There are several bits which exhibit special behavior for a logic

engine. These bits consist of two “tags” to be used in the execution

of logic. There is an input tag and an output tag. Stimulus is

connected to the output tag which then controls the status of the

input tag. The purpose for this is to allow a user to assign an

important bit such as “stop status” to a hardware input so that when

reviewing the logic the user will be able to use the “stop status” bit

as opposed to the “DLX input 1” bit. This is to help a user create his

logic in a way which is easier to follow. See the example below for

clarification: