Rockwell Automation 1503VC IntelliVAC Plus Contactor Control Module User Manual

Page 305

Advertising
background image

B-130

Parameters

1503-UM054C-EN-P – June 2013

Average Number of Operations per Time Unit on IB1
[IB 1 Average Operations per Time Unit]

Parameter Number:

253,209,165,121,76.

Access rule:

Get/Set

Data Type:

USINT

Object Mapping:

0x384-1-43

Group:

Diagnostics

Units:

-

Minimum Value:

0

Maximum Value:

2

Default Value:

0

This parameter allows the user to view and set the status of the

Average Number of Operations per Unit Time for IB1. The Time

Unit is used to set the period over which the Average number of

Operations is to be calculated for. See “Average Operations”

Counter in Chapter 4 for a detailed description of this feature.

Table B.33 – Time Unit for Average # Close Operators for IB1

Value

Enum Text

Description

0

Hour

Average Close operations per Hour for IB1

1

Day

Average Close operations per Day for IB1

2

Week

Average Close operations per Week for IB1


Average Number of Operations on IB1
[IB 1 Average Operations Value]

Parameter Number:

254,210,166,111,77.

Access rule:

Get

Data Type:

UDINT

Object Mapping:

0x384-1-44

Group:

Diagnostics

Units:

Avg. # of Close operations per unit time

Minimum Value:

0

Maximum Value:

0xFFFFFF

Default Value:

0

This parameter allows the user to view the status of the Average

Number of Close Operations, for IB1, as measured per the Unit Time

set in parameter #253. The Time Unit is used to set the period over

which the Average number of Operations, for IB1, is to be calculated

for. See “Average Operations” Counter in Chapter 4 for a detailed

description of this feature.

Advertising