Sat iii controller, Sat 3p controller, Wcc3.exe screen descriptions – WattMaster WM-WCC3-TGD-01B User Manual

Page 219: Energy consumption screen, Wcc iii technical guide 3-105, Sat iii

Advertising
background image

WCC III Technical Guide

3-105

WCC3.EXE SCREEN DESCRIPTIONS

8

7

SAT ADDRESS

2

1

4

8

A 3 WIRE ROOM SENSOR WILL NOT
REQUIRE A LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32

16

64

L4

L3

L2

L1

L6

L5

L7

L11

L12

ON OFF

L10

L9

ON OFF

L15

L16

L14

L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF

PULSE INPUT

OPTION 1

TEST

OPTION 3

OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

A 2 WIRE ROOM SENSOR WILL REQUIRE
A 300 OHM LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

A 4 TO 20 mA SENSOR WILL REQUIRE A
50 OHM LOAD RESISTOR WHEN SET FOR
A 1 VOLT INPUT, OR A 250 OHM LOAD
RESISTOR WHEN SET FOR A 5 VOLT INPUT.

CURRENT
INPUT

THERMISTOR
INPUT

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

0 - 10V

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

PROGRAMMABLE CONTROLLER

SAT III

EACH CONTACT
IS RATED FOR
24VAC OR VDC
@ .5 AMP MAX

0-15VDC
OUTPUT

MIN LOAD
IS 1K OHM
RESISTIVE
VDC ONLY

TO HSS EXPANSION BOARDS.
UP TO TWO BINARY INPUT
BOARDS AND UP TO TWO
V-OUT RELAY BOARDS
MAY BE CONNECTED TO A
SAT III CONTROLLER.

SAT III CONTROLLER

24VAC
FUSED

24

VAC

GN
D

GROUND

WARNING:

OBSERVE POLARITY

BETWEEN THE SAT III CONTROLLER
AND THE SAT 3P CONTROLLER -
GROUND CONNECTIONS MUST BE THE

SAME.

TO OTHER

SAT III OR TO
WCC III - MCD

24VAC

120VAC

PULSE 1
PULSE 2
PULSE 3
PULSE 4
PULSE 5
PULSE 6
PULSE 7
PULSE 8
STAT REC
STAT XMIT
LOCAL SET
STATUS

COMM

ADD

1

2

4

8

16

32

64

128

ADDRESS

SATIII-P

PULSE METER BOARD

ATTMASTER CONTROLS

YS102268 REV0

MADE IN USA

P1

P2

P3

P4

P5

P6

P7

P8

GND

GND

POWER

SEL

TEST

LOCAL

L DIS

OPT 1

OPT 2

OPT 3

SH

R

T

24 VAC

GND

OPTIONS

PULSE INPUTS

“P” MODE ADDRESSING NOTES

SAT III ADDRESSING STARTSAT

ADDRESS NUMBER 8.

EACH "P" MODE SAT III TAKES UP

(8) SAT III LOGICAL ADDRESSES.

THERE ARE ONLY (8) USED ACTIVE

INPUTS PER SAT 3P.

ANALOG INPUT #1 (PULSE INPUT #1)

ON EACH SAT III ADDRESS IS ACTIVE.

ALL OTHER INPUTS AND OUTPUTS ON

THE SAT 3P ARE NOT FUNCTIONAL.

TOTAL WIRING FOR EACH INPUT NOT

TO EXCEED 100 FEET.

USE 18 GAUGE TWISTED PAIR WITH

SHIELD FOR EACH PULSE METER

CONNECTION.

CONNECT THE SHIELD WIRE TO GND.

SAT 3P Typical Wiring Diagram

Use the following Pulse Meter
E-Mon D-Mon Series 2000 with
P2 Pulser Output Module option.

Times eight Pulse Meters.

KW

METER

KW

METER

KW

METER

KW

METER

KW

METER

KW

METER

KW

METER

KW

METER

SAT 3P

CONTROLLER

WARNING:

OBSERVE POLARITY

BETWEEN THE SAT 3P CONTROLLER
AND THE SAT III CONTROLLER -
GROUND CONNECTIONS MUST BE THE
SAME.

120VAC WIRING IS BY OTHERS

THE VA RATING FOR THE SAT III IS 15 VA.
THE VA RATING FOR THE SAT 3C IS 10 VA.
THE VA RATING FOR THE SAT 3D IS 10 VA.
THE VA RATING FOR THE SAT 3P IS 3 VA.

TO OTHER SAT III CONTROLLERS,
SAT 3C CONTROLLERS, SAT 3D
CONTROLLERS, OR SAT 3P CONTROLLERS,
OR TO THE WCC III - MCD COMPUTER.
WIRE "R" TO "R", "T" TO "T", "SHLD" TO "SHD"

KW

METER

SAT III Typical Wiring Diagram

Use the following Pulse Meter
E-Mon D-Mon Series 2000 with the P2 Pulser
Output Module option
Can only connect One Pulse Meter per SAT III.

SAT III Ain #1 jumper set for 0-5V input,

Vout #1 output voltage programmed for

constant 5 volt output. PULSE INPUT switch
"ON".

(+)

(-)

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

(-)

(+)

Energy Consumption Screen

Advertising
This manual is related to the following products: