Wcc iii installation guide, Satellite controllers - general dimensions, Satellite controller dimensions – WattMaster WM-WCC3-TGD-01B User Manual

Page 511: Wcc iii technical guide 12-15, Ch in a, Chi n a, Sat iii

Advertising
background image

12. WCC III INSTALLATION

GUIDE

WCC III Technical Guide

12-15

Satellite Controllers - General Dimensions

8

7

SAT ADDRESS

2
1

4

8

A 3 WIRE ROOM SENSOR WILL NOT
REQUIRE A LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

WattMaster Controls Inc.

BINARY
INPUTS

BINARY
INPUTS

L8

ON OFF

128

32
16

64

L4
L3
L2
L1

L6
L5

L7

L11

L12

ON OFF

L10
L9

ON OFF

L15

L16

L14
L13

C

H

4

3

5
6

2

1

LOCAL SET

STATUS 2

STATUS 3

STATUS 1

HSS XMIT

LOCAL SET

LOCAL SET DISABLE

BATT ON/ OFF

PULSE INPUT

OPTION 1

TEST

OPTION 3

OPTION 2

ON OFF

STATUS

HSS REC

SAT XMIT

SAT REC

ANALOG INPUT

JUMPER SELECTION

A 2 WIRE ROOM SENSOR WILL REQUIRE
A 300 OHM LOAD RESISTOR WHEN SET
FOR A 1 VOLT INPUT.

A 4 TO 20 mA SENSOR WILL REQUIRE A
50 OHM LOAD RESISTOR WHEN SET FOR
A 1 VOLT INPUT, OR A 250 OHM LOAD
RESISTOR WHEN SET FOR A 5 VOLT INPUT.

CURRENT
INPUT

THERMISTOR
INPUT

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

0 TO 10V
INPUT

0 TO 5V
INPUT

0 TO 1V
INPUT

0 - 10V

0 - 1V

0 - 5V

0 - 10V

THERM

0 - 1V

0 - 5V

THERM

0 - 1V

0 - 5V

0 - 10V

THERM

PROGRAMMABLE CONTROLLER

SAT III

H

C

COM

CHANNEL

2

1

3 4

2

1

3 4

5 6 7 8

5 6 7 8

V

OUT

GND

L
O
A
D

+V

ATI

10

A

2

5

0

V

A

C

~

5A

3

0

V

D

C

SA

VD

E

G5

Q-

1

A

4

OM

R

O

N

DC

2

4

V

CH

IN

A

10A

2

5

0

V

A

C

~

5

A

3

0

VDC

SA

VD

E

G5

Q

-1

A

4

OM

R

O

N

DC

2

4

V

CH

IN

A

1

0

A

2

50V

A

C

~

5A

3

0

V

D

C

SA

VDE

G5

Q

-1

A

4

OM

R

O

N

DC

2

4

V

CH

IN

A

10

A

2

50

V

A

C

~

5A

3

0

V

D

C

SA

VDE

G5

Q

-1

A

4

OM

R

O

N

DC

2

4

V

CHI

N

A

1

2

3

4

5

6

1

2

3

4

5

6

+V SENSORS

R1

R2

1

2

R3

R4

R5

R6

3

4

5

6

C

7

8

C

H

V

OUT

GN

D

7

8

R

R7

R8

7

8

AT

EACH CONTACT
IS RATED FOR
24VAC OR VDC
@ .5 AMP MAX

0-15VDC
OUTPUT

MIN LOAD
IS 1K OHM
RESISTIVE
VDC ONLY

M

ADE

IN

TH
E

U

S

A

K1
6

K1
5

K1
4

K1
3

V16

V15

V14

V13

11.90

11.25

5.85

7.18

GND

24
V

A

C

24 VAC
POWER

SAT

COMMUNICATION

R

T

SHIE

L

D

IN / OUT

HSS EXP

COMM

SATIII SIDE PROFILE VIEW (POWER INPUT)

SATIII SIDE PROFILE VIEW (SAT COMM & HSS PORT)

SATIII SIDE PROFILE VIEW (ANALOG IN/OUT - CONTROL OUTPUT)

3.00

7.18

Figure 12-13: SAT III controller dimensions. All dimensions are in inches.

Figure 12-14: SAT 3C/D/F controller dimensions. All dimensions are in inches.