3 swing, 1 swing - overview, Swing – Metrohm tiamo 2.4 (process analysis) User Manual

Page 1235

Advertising
background image

■■■■■■■■■■■■■■■■■■■■■■

5 Method

tiamo 2.4 (for Process Analysis)

■■■■■■■■

1219

Display message
A message is displayed and the determination is stopped.
Stop determination
The determination is stopped and the next determination of the series
is started.
Stop determination and series
The determination as well as the series are stopped. An Exit track will
be started if there is one defined.

Parameters

Shift rate

Selection of the speed at which the sample rack rotates.

Input range

3 - 20 °/s

Default value

20 °/s

Shift direction

Selection of the shift direction of the sample rack.

Selection

auto | + |

Default value

auto

auto
The direction of rotation with the smallest angle of rotation is selected
automatically.
+
Rack rotates counterclockwise.

Rack rotates clockwise.

Swing rate

Selects speed of the robotic arm when moving to a rack position or a spe-
cial beaker (only with multiple row sample racks).

778, 789, 814, 815, 855, 864, 874
Input range

10 - 55 °/s

Default value

55 °/s

5.6.7.3

SWING

5.6.7.3.1

SWING - Overview

Dialog window: Method

SWING Properties... SWING - 'Command name'

Command for swinging the robotic arm. This command is only execut-
able if the Sample Processor is equipped with a 786 Swing Head with a
robotic arm.