Wiring

Devices in the range 145 ... 695 A (75 ... 370 kW)

4

121

EDS94SPP101 EN 7.1

4.6.6

Devices in the range 145 ... 695 A (75 ... 370 kW)

Device size 8S

SSP94KL08S

Fig. 4-26

Arrangement of the power connections

Tip!

The barrier between mains input and power terminals can be dismounted to

have more free space for wiring.

Motor

Terminal X105

Marking

Description

U

V

W

Motor phases

SSP94KL0X8

Connection for the PE conductor on the motor side with M8 ring

cable lug

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 8S:

Flexible

With wire end ferrule

95

000

14

124

Inbus 5

M8 ring cable lug

95

000

9.5

84

WAF 13