Safety instructions

General safety and application notes for Lenze controllers

3

30

EDS94SPP101 EN 7.1

Electrical connection
When working on live controllers, observe the applicable national regulations for the

prevention of accidents (e.g. VBG 4).
The electrical installation must be carried out according to the appropriate regulations

(e.g. cable cross-sections, fuses, PE connection). Additional information can be obtained

from the documentation.
The documentation contains information on the installation according to EMC (shielding,

earthing, arrangement of filters, and installation of the cables). Also observe this

information with regard to drive controllers labelled with CE marking. The manufacturer

of the system or machine is responsible for the compliance of the limit values required in

connection with EMC legislation. In order to observe the limit values for radio interference

emissions effective at the installation site, you have to mount the drive controllers into

housings (e. g. control cabinets). The housings haveto enableanEMC-compliantstructure.

Particularly observe that, for instance, control cabinet doors preferably are metallically

connected to the housing in a circumferential manner. Reduce openings or apertures

through the housing to a minimum.
Lenze controllers can cause a DC current in the PE conductor. If a residual current device

(RCD) is used for the protection in the case of direct or indirect contact on a three-phase

supplied controller, only one residual current device of type B is permissible on the current

supply side of the controller. If the controller is supplied with one phase, also a residual

current device (RCD) of type A may be used. Apart from the use of a residual current device

(RCD) also other protective measures can be used, like for instance isolation from the

environment by double or reinforced insulation or isolation from the supply system by a

transformer.

Operation
If necessary, systems including controllers must be equipped with additional monitoring

and protection devices according to the valid safety regulations (e.g. law on technical

equipment, regulations for the prevention of accidents). The controllers can be adapted to

your application. Please observe the corresponding information given in the

documentation.
After the controller has been disconnected from the supply voltage, all live components

and power connections must not be touched immediately because capacitors can still be

charged. Please observe the corresponding stickers on the controller.
All protection covers and doors must be shut during operation.
Notes for UL-approved systems with integrated controllers: UL warnings are notes that

only apply to UL systems. The documentation contains special UL notes.

Safety functions
Special controller variants support safety functions (e.g. ”safe torque off”, formerly ”safe

standstill”) according to the requirements of appendix I No. 1.2.7 of the EC Directive

”Machinery”98/37/EC, EN 954-1 category 3 and EN 1037. Strictly observe the notes onthe

safety functions given in the documentation on the respective variants.

Maintenance and servicing
The controllers do not require any maintenance if the prescribed operating conditions are

observed.