Accessories (overview), Stop – Lenze 9400 Manual User Manual

Page 369

Advertising
background image

Accessories (overview)

Communication modules

Ethernet interface

9

369

EDS94SPP101 EN 7.1

Use of pluggable terminal strips

Stop!

To avoid damage to pluggable terminal strips and contacts:
Wire pluggable terminal strips prior to connection!

Use of the pluggable terminal strip with spring connection

E94YCEH007B

Ethernet connection

E94ZCEH004

PIN

Pin assignment for port 1 (connection A1)

Pin assignment for ports 2 - 8

(connections A2 ... A8)

MDI (not crossed)

MDIX (crossed)

1

Tx +

Rx +

Rx +

2

Tx -

Rx -

Rx -

3

Rx +

Tx +

Tx +

4

-

-

-

5

-

-

-

6

Rx -

Tx -

Tx -

7

-

-

-

8

-

-

-

Note!

Plug/remove the Ethernet cable plug vertically into/from the socket to make

sure that the RJ45 socket will not be damaged.

Advertising