Power supply modules

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 400 V

6

221

EDS94SPP101 EN 7.1

6.3.2

Operation at rated mains voltage 400 V

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

400

320 - 0 % ... 440 + 0 %

45 - 0 % ... 65 + 0 %

Input data

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94APNE0104

400

50/60

8

6

3

E94APNE0364

400

50/60

29

21.8

3

E94APNE1004

400

50/60

82

61

3

E94APNE2454

400

50/60

200

150

3

c

Temperature in the control cabinet

Voltage

Continuous input power

Type

[V]

S

L

[kVA]

E94APNE0104

400

5.5

E94APNE0364

400

20.1

E94APNE1004

400

56.7

E94APNE2454

400

138

Output data

Basis of the data
Mains

Voltage

U

DC

[V]

Voltage range

U

DC

[V]

Frequency range

f [Hz]

2/PE DC

565

455 - 0 % ... 620 + 0 %

-

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94APNE0104

565

0 (DC)

10

7.5

2

E94APNE0364

565

0 (DC)

36

27

2

E94APNE1004

565

0 (DC)

100

75

2

E94APNE2454

565

0 (DC)

245

184

2

c