background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHN0026

9

458

EDS94SPP101 EN 7.1

Connection of the motor holding brake

Terminal X107

Labelling

Description
Connection of the motor holding brake:

BD1

BD2

+ (Lenze: WH)

- (Lenze: BN)

E94AZHN0026: 180 V DC, max. 0.75 A

Ensure correct polarity!

L1

L2/N

Supply voltage of the motor holding brake

SSP94A6107

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end

ferrule

Stripping length or contact length: 8 mm

Terminal data

Control connection

Terminal X117

Labelling

Description

DI

Digital input

GI

GND digital in

DO

Signalling output

24V

24-V supply by safely separated power supply unit (SELV/PELV)

SSP94A6117

GND

GND digital out

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end

ferrule

Stripping length or contact length: 8 mm

Digital output DO
State

Description

HIGH

No fault

LOW

Fault

z

Supply voltage of the motor holding brake is missing

z

Motor holding brake is not connected

z

Brake cable is defective

– Open circuit

– Short circuit

z

Supply voltage of the motor brake control is missing