Rated data (devices for 400/500V mains)

Operation at rated mains voltage 230 V

4

50

EDS94SPP101 EN 7.1

4.3.2

Operation at rated mains voltage 230 V

Device size 1 ... 6

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

230

180 - 0 % ... 264 + 0 %

45 - 0 % ... 65 + 0 %

2/PE DC

325

260 - 0 % ... 370 + 0 %

-

Mains current at I

aN

Output power

Motor power

(typical)

with external

mains choke

without external

mains choke

U, V, W

4 pol. ASM

Type

I

LN

[A]

I

LN

[A]

S

aN

[kVA]

P

aN

[kW]

P

aN

[hp]

E94ASxE0024

1.5

2.1

0.5

0.18

0.25

E94ASxE0034

2.5

3.5

0.9

0.37

0.5

E94ASxE0044

3.9

5.5

1.4

0.75

1

E94ASxE0074

7.0

9.9

2.5

1.5

2

E94ASxE0134

12.0

16.8

4.7

3

4

E94ASxE0174

15.0

21.0

5.9

4

5.5

E94ASxE0244

20.5

29.0

8.4

5.5

7.5

E94ASxE0324

-

29.0

11.5

7.5

10

E94ASxE0474

-

43.0

16.9

11

15

E94ASxE0594

-

54.0

21.2

15

20

Device size 7

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

230

180 - 0 % ... 264 + 0 %

45 - 0 % ... 65 + 0 %

Mains current at I

aN

Output power

Motor power

(typical)

with external

mains choke

without external

mains choke

U, V, W

4 pol. ASM

Type

I

LN

[A]

I

LN

[A]

S

aN

[kVA]

P

aN

[kW]

P

aN

[hp]

E94ASxE0864

-

79.0

30.8

22

29

E94ASxE1044

-

95.0

37.3

30

40