Power supply modules – Lenze 9400 Manual User Manual

Page 231

Advertising
background image

Power supply modules

Device description

Devices in the range 10 ... 36 A (4 ... 18 kW)

6

231

EDS94SPP101 EN 7.1

Standard device
Pos.

Description

X11

24 V supply

X12

4 digital outputs
1 digital input

Nameplate, retractable

Setting of mains voltage/brake chopper threshold

Upper cap

The LED display enables fast indication of several operating states.

LED

Labelling

Colour

Description

-

-

-

OVERHEAT

Red

Overtemperature

MAINS

Green

Mains voltage OK

BRCHOP FAIL

Red

Short circuit on brake chopper

24 V

Green

24 V supply voltage OK

SSP94LED21

BRCHOP ON

Yellow

Brake chopper active

Pos.

Symbol

Description

Long discharge time: All power terminals carry hazardous voltages for at

least 3 minutes after mains disconnection!

High discharge current: Fixed installation and PE connection to EN 61800-5-1

required!

Electrostatic sensitive devices: Before working on the device, personnel must

ensure that they are free of electrostatic charge!

Installation backplane
Pos.

Description

X111

Mains (supply from above, e.g. from top filters)
DC-bus voltage (compatible with 9300 series)

X112

Mains (supply from below, e.g. from built-on filter)
External brake resistor

X109

DC-bus busbar +

Direct connection of

9400 axis modules,

device sizes 1 ... 3

X110

DC busbar -

EMC shield clamp

Advertising