Multi-axis controllers, Rated data overview, Output data – Lenze 9400 Manual User Manual

Page 164

Advertising
background image

Multi-axis controllers

Rated data

Overview

5

164

EDS94SPP101 EN 7.1

Output data

Voltage

Frequency

1)

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C

c

max. +55 °C

c

E94AMxE0024

0 - 230/400/500

0 - 599

1.5/1.5/1.3

1.1/1.1/1.0

3

E94AMxE0034

0 - 230/400/500

0 - 599

2.5/2.5/2.2

1.9/1.9/1.7

3

E94AMxE0044

0 - 230/400/500

0 - 599

4/4/3.5

3/3/2.6

3

E94AMxE0074

0 - 230/400/500

0 - 599

7/7/6.1

5.3/5.3/4.6

3

E94AMxE0094

0 - 230/400/500

0 - 599

9.3/9.3/8.2

7.0/7.0/6.2

3

E94AMxE0134

0 - 230/400/500

0 - 599

13/13/11.4

9.8/9.8/8.6

3

E94AMxE0174

0 - 230/400/500

0 - 599

16.5/16.5/14.4

12.4/12.4/10.8

3

E94AMxE0244

0 - 230/400/500

0 - 599

23.5/23.5/20.6

17.6/17.6/15.5

3

E94AMxE0324

0 - 230/400/500

0 - 599

32.0/32.0/25.9

24.0/24.0/19.4

3

c

Temperature in the control cabinet

1)

The limitation to 599 Hz does not apply to the ”servo control” modes (see C00006 = 1 or 2). Generally applies: the

output frequency is limited to 1/8 of the selected chopper frequency (see C00018).

Power loss P

V

[W]

Type

U

Lr

= 230 V

U

Lr

= 400 V

U

Lr

= 500 V

when controller is inhibited

E94AMxE0024

65

80

95

40

E94AMxE0034

75

95

110

E94AMxE0044

90

120

130

E94AMxE0074

105

145

170

E94AMxE0094

130

170

205

E94AMxE0134

160

215

255

E94AMxE0174

185

255

300

E94AMxE0244

235

320

385

E94AMxE0324

290

405

490

Advertising