Single-axis controllers – Lenze 9400 Manual User Manual

Page 134

Advertising
background image

Single-axis controllers

Wiring

Devices in the range 145 ... 695 A (75 ... 370 kW)

4

134

EDS94SPP101 EN 7.1

DC bus

Terminal X100

Labelling

Description

Connection with ring

cable lug for M10

+Ug

-Ug

Alternative option for DC-bus voltage connection (compatible to

9300 series).

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 10:

E94ASxE4604

E94ASxE5724

E94ASxE6354

E94ASxE6954

2 x 400

3 x 150

2 x 750 mcm

3 x 350 mcm

19

168

WAF 16

Operation with DC supply
ForoperationwithDCsupply, theinternal fansmust beconnected viathe internalterminal

FK103 to the 400/500 V AC mains voltage.
When opening the upper housing cover, you will find the pluggable terminal FK103 at the

top in the device on the switched-mode power supply card.

94SSPGG852

Interface card

Switched-mode power supply card

FK103

Fan voltage terminal

Remove the cable bridges of the terminal. Then, connect the mains voltage to

FK103.101/100.

FK103

Labelling

Description

101103 NC NC 100102

101

Fan L1

by default bridged

103

Mains phase

(internal)

NC

not assigned

NC
100

Fan L2

by default bridged

SSP94FK103

102

Mains phase

(internal)