3 operation at a rated mains voltage of 500 v, Operation at a rated mains voltage of 500 v, Regenerative power supply modules – Lenze 9400 Manual User Manual
Page 270: Input data (on the supply side)
Advertising
Regenerative power supply modules
Rated data (devices for 400/500V mains)
Operation at a rated mains voltage of 500 V
7
270
EDS94SPP101-7.1
7.3.3
Operation at a rated mains voltage of 500 V
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
LN
[V]
U
LN
[V]
f [Hz]
3/PE AC
500
400 - 0 % ... 550 + 0 %
45 ... 65
Input data (on the supply side)
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94ARNE0134
In motor mode
500
50/60
26
19.5
3
In generator mode
500
50/60
13
9.8
3
E94ARNE0244
In motor mode
500
50/60
47
35
3
In generator mode
500
50/60
23.5
17.6
3
c
Temperature in the control cabinet
Voltage
Continuous input power
Type
[V]
S
L
[kVA]
E94ARNE0134
In motor mode
500
22.5
In generator mode
500
11.2
E94ARNE0244
In motor mode
500
40.7
In generator mode
500
20.3