Accessories (overview), Elements of the motor brake control, Standards – Lenze 9400 Manual User Manual

Page 461

Advertising
background image

Accessories (overview)

Motor holding brake control modules

Motor holding brake control module E94AZHY0026

9

461

EDS94SPP101 EN 7.1

Elements of the motor brake control

Pos.

Description

Nameplate

Connection of standard device

X107

Connection of supply and brake

Standards

Conformity and approval
Conformity

CE

2006/95/EC

Low-Voltage Directive

Approval

UR

UL 508C

Industrial Control Equipment Recognised

(file no. E132659) for USA

Protection of persons and equipment
Enclosure

EN 60529

IP00

Protective measures

Against short circuit

EMC
Noise emission

EN 61800-3

Conducted, category C2.

Noise immunity

EN 61800-3

Burst on mains cable:

2 kV/5 kHz

Burst on control cable:

2 kV/5 kHz

Surge on mains cable:

1 kV (1.2 μs/50 μs;

phase - phase)
2 kV (1.2 μs/50 μs; phase - PE)

Operating conditions
The operating conditions correspond to the operating conditions for the standard device

to which the DC-feeding point is connected.

Environmental conditions
Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 ... +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 ... +70 °C)

Operation

IEC/EN 60721-3-3

3K3 (-10 ... +55 °C)

Site altitude

0 ... 4000 m amsl

1000 ... 4000 m amsl: current derating of 5 %/1000 m

Pollution

EN 61800-5-1

Pollution degree 2

Vibration resistance

(9.81 m/s

2

= 1 g)

Transport

IEC/EN 60721-3-2

2M2

EN 61800-2

2 ... 9 Hz: amplitude 3.5 mm
10 ... 200 Hz: acceleration resistant up to 10 m/s

2

200 ... 500 Hz: acceleration resistant up to 15 m/s

2

Operation

Germanischer Lloyd

5 ... 13.2 Hz: amplitude ±1 mm

13.2 ... 100 Hz: acceleration resistant up to 0.7 g

EN 600068-2-6

10 ... 57 Hz: amplitude 0.075 mm
57 ... 150 Hz: acceleration resistant up to 10 m/s

2