Rated data (devices for 400/500V mains)

Operation at rated mains voltage 230 V

6

220

EDS94SPP101 EN 7.1

Output current and output power

100 %

5-s cycle

3-min cycle

Type

I

DC

[A]

P

DC

[kW]

I

DC

[A]

P

DC

[kW]

I

DC

[A]

P

DC

[kW]

E94APNE0104

10

2.1

40

8.4

15

3.2

E94APNE0104

+ E94AZMP0084

10

2.8

40

11.2

15

4.2

E94APNE0364

36

7.5

108

22.5

54

11.3

E94APNE0364

+ E94AZMP0294

36

10.1

108

30.3

54

15.5

E94APNE1004

100

20.8

200

62.4

150

31.2

E94APNE1004

+ E94AZMP0824

100

27.9

200

83.7

150

41.9

E94APNE2454

245

51

368

153

368

76.5

E94APNE2454

+ E94AZMP2004

245

68.5

368

206

368

103

100 %

Permanent rated values

5-s cycle

Cycle for the second-range
(0.5 s overload/4.5 s recovery time with 75 % of the permanent rated value)

3-min cycle

Cycle for the minute-range
(60 s overload/120 s recovery time with 75 % of the permanent rated value)

Internal brake chopper data

R

Bmin

[Ω]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type
E94APNE0104

18.0

21.7

8.5

7.9

1.1

4.3

0.5

0.5

E94APNE0364

6.0

65.0

25.4

29.1

5.1

3.0

0.5

0.5

E94APNE1004

2.5

156

60.8

62.7

9.8

3.6

0.5

0.5

E94APNE2454

1.4

279

109

112

17.5

3.6

0.5

0.5

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS - important for the dimensioning of the cables

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time

t

Z

- t

on

Recovery time

t

fp

Maximum running time without initial load and compliance with the recovery

time

Advertising