Single-axis controllers, 400 v – Lenze 9400 Manual User Manual

Page 72

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Overcurrent operation

4

72

EDS94SPP101 EN 7.1

400 V

Type

I [A] in a cycle of 3 minutes d

f = 2 kHz

f = 4 kHz

f = 8 kHz

f = 16 kHz

E94ASxE0024

2.8

1.4

2.8

1.4

2.3

1.1

-

-

E94ASxE0034

4.7

2.4

4.7

2.4

3.8

1.9

-

-

E94ASxE0044

7.5

3.8

7.5

3.8

6.0

3.0

-

-

E94ASxE0074

13.2

6.6

13.2

6.6

10.5

5.3

-

-

E94ASxE0134

24.4

12.2

24.4

12.2

19.5

9.8

-

-

E94ASxE0174

31.0

15.5

31.0

15.5

24.8

12.4

-

-

E94ASxE0244

44.2

22.1

44.2

22.1

35.3

17.6

-

-

E94ASxE0324

57.6

28.8

57.6

28.8

48.0

24.0

-

-

E94ASxE0474

70.5

35.3

70.5

35.3

61.6

30.6

-

-

E94ASxE0594

88.5

44.3

88.5

44.3

61.4

30.7

-

-

E94ASxE0864

129

64.5

129

64.5

109

55.0

-

-

E94ASxE1044

156

78.0

156

78.0

118

58.2

-

-

E94ASxE1454

218

109

218

109

164

81.2

-

-

E94ASxE1724

258

129

258

129

194

96.3

-

-

E94ASxE2024

303

152

303

152

228

113

-

-

E94ASxE2454

368

184

314

157

240

120

-

-

E94ASxE2924

438

219

374

187

286

143

-

-

E94ASxE3664

549

275

468

234

359

179

-

-

E94ASxE4604

690

345

552

276

391

193

-

-

E94ASxE5724

858

429

686

343

429

217

-

-

E94ASxE6354

953

476

762

381

476

241

-

-

E94ASxE6954

1043

521

834

417

521

264

-

-

Advertising