Single-axis controllers, For the selection ”mode 2 – Lenze 9400 Manual User Manual

Page 58

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 400 V

4

58

EDS94SPP101 EN 7.1

For the selection ”Mode 2“:

Output currents [A] at switching frequency

2 kHz

Type

I

aN2

I

aNhc

I

aMhc

I

aMre

E94ASxE1454

145

177

195

168

E94ASxE1724

172

212

233

201

E94ASxE2024

202

260

286

247

E94ASxE2454

245

315

347

299

E94ASxE2924

292

395

434

375

E94ASxE3664

366

480

528

456

E94ASxE4604

460

600

660

570

E94ASxE5724

572

658

724

625

E94ASxE6354

635

745

820

708

E94ASxE6954

695

800

880

760

I

aN2

Rated value of continuous output current at a frequency of ≥ 0 Hz
(standard operation)

I

aNhc

Increased continuous output current at a frequency of ≥ 0 Hz

I

aMhc

Maximum output current (overload current)

z

Periodic load change of 60 s with I

aMhc

and recovery time of 120 s with I

aMre

I

aMre

Maximum output current during the recovery time

Sinusoidal filter assignments changed for this operating mode:

Motor cable lengths when sinusoidal filters and line filters are used

Compliance with the EMC protection requirement C2

Type

Setting C01199

Sinusoidal filter

shielded

unshielded

Switching

frequency

E94ASxE2024

”Mode 2”

EZS3-350A200

150 m

- m

2 kHz

or

4 kHz

E94ASxE2924

EZS3-480A200

E94ASxE4604

EZS3-480A200

(2 in parallel)