Accessories (overview)

Communication modules

PROFIBUS

9

379

EDS94SPP101 EN 7.1

External voltage supply

Note!

Always use a separate power supply unit in every control cabinet and safely

separate it according to EN 61800-5-1 (”SELV”/”PELV”) in the case of external

voltage supply and larger distances between the control cabinets.

The external voltage supply of the communication module is required if communication

via the bus system is to continue in the event of a power supply failure of the standard

device.

ƒ

The external voltage supply of the communication module is required if

communication is to continue when the power supply of the standard device fails.

ƒ

Access to parameters of a standard device disconnected from the mains is not

possible.

ƒ

The external voltage supply is effected via the 2-pole plug connector.

Connection of the 2-pin plug connector (X200):

Designation

Explanation

+

U = 24 V DC (20.4 V - 0 % ... 28.8 V + 0 %)

I = 130 mA

-

Reference potential for external voltage supply

Connect the communication module to the bus system according to the description

( 380).

Terminal data

Area

Values

Electrical connection

Plug connector with screw connection

Possible connections

rigid:

1.5 mm

2

(AWG 16)

flexible:

without wire end ferrule

1.5 mm

2

(AWG 16)

with wire end ferrule, without plastic sleeve

1.5 mm

2

(AWG 16)

with wire end ferrule, with plastic sleeve

1.5 mm

2

(AWG 16)

Tightening torque

0.5 ... 0.6 Nm (4.4 ... 5.3 lb-in)

Stripping length

6 mm