Accessories (overview)

Safety modules

SM100

9

408

EDS94SPP101 EN 7.1

Safety instructions

Danger!

If the request for the safety function is cancelled, the drive will restart

automatically.
You must provide external measures which ensure that the drive only restarts

after a confirmation (EN 60204).

Danger!

Unexpected motor rotation possible
In the event of a short-circuit between two power transistors, a residual

movement of the motor of up to 180 °/number of pole pairs may occur!

(Example.: 4-pole motor ⇒ residual movement max. 180 °/2 = 90 °)
Possible consequences:

ƒ

People may be injured by the machine movements (unexpected start-up).

Protective measures:

ƒ

The residual movement must be considered in the risk analysis, e.g. safe

torque off for main spindle drives.

Warnings!

ƒ

Maximum surrounding air temperature: 55 °C.

ƒ

External fuse for 24 Vdc supply voltage. Rated 4 A DC fuse UL248-14.