1 introduction, 1 terminology and abbreviations used, Terminology and abbreviations used – Lenze 9400 Manual User Manual

Page 310: Dc-bus operation

Advertising
background image

DC-bus operation

Introduction

Terminology and abbreviations used

8

310

EDS94SPP101 EN 7.1

8.1

Introduction

8.1.1

Terminology and abbreviations used

ƒ

DC bus
The energy store in the controller or supply module from which the controller

modulates the AC voltage for the motor. The DC buses of several controllers can be

networked.

ƒ

DC bus
Electrical connection of the DC connections of several controllers via cable or busbar.

ƒ

DC-voltage level
DC-voltage level in the DC bus

ƒ

Power supply module
Module with AC mains connection used to supply the DC bus of a drive system with DC

voltage.

ƒ

Regenerative power supply module
Power supply module with additional power regeneration into the AC mains

ƒ

Multi-axis controllers (Multi Drive)
Controllers for connection to a DC bus. Multi-axis controllers have no AC mains

connection and no brake chopper.

ƒ

Single-axis controllers (Single Drive)
Controllers for connection to an AC mains or a DC bus. Single-axis controllers have an

integrated brake chopper.

ƒ

Brake chopper
Switching element in the controller used to dissipate excess energy in the DC bus via

a brake resistor.

ƒ

Brake resistor
High-performance resistor used to convert excess energy in the DC-bus into heat.

ƒ

Braking operation
Motor operation in generator mode with energy feedback from the motor to the

controller.