Single-axis controllers – Lenze 9400 Manual User Manual

Page 122

Advertising
background image

Single-axis controllers

Wiring

Devices in the range 145 ... 695 A (75 ... 370 kW)

4

122

EDS94SPP101 EN 7.1

External brake resistor

Terminal X105

Labelling

Description

Rb1

Rb2

Connection of external brake resistor

Connection for the PE conductor with M8 ring cable lug.

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 8S:

Flexible

With wire end ferrule

95

000

14

124

Inbus 5

DC bus

Terminal X100

Labelling

Description

+UG

-UG

Alternative option for DC-bus voltage connection (compatible to

9300 series).

Terminal data

Max. conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 8S:

Flexible

With wire end ferrule

95

000

14

124

Inbus 5

Tip!

Now mount the barrier between mains input and power terminals, if had been

removed to have more free space for wiring.

Advertising