Single-axis controllers, General data and operating conditions, V/f control mode – Lenze 9400 Manual User Manual

Page 43

Advertising
background image

Single-axis controllers

General data and operating conditions

4

43

EDS94SPP101 EN 7.1

Longer motor cables can be achieved when line filters are used in combination with

sinusoidal filters. Further conditions to be observed:

ƒ

V/f control mode

ƒ

Switching frequency is permanently set (C00018)

Motor cable lengths when sinusoidal filters and line filters are used

Compliance with the EMC protection requirement C2

Type

RFI filter

Mains filter

Sinusoidal filter

shielded

unshielded

Switching

frequency

E94ASxE0024

-

E94AZMS0034

EZS3-004A200

100 m

300 m

4 kHz

or

8 kHz

E94ASxE0034
E94ASxE0044

-

E94AZMS0094

EZS3-010A200

E94ASxE0074
E94ASxE0134

-

E94AZMS0184

EZS3-024A200

E94ASxE0174
E94ASxE0244

-

E94AZMS0314

EZS3-037A200

E94ASxE0324

E94AZRS0544

-

EZS3-048A200

150 m

300 m

4 kHz

or

8 kHz

E94ASxE0474

EZS3-061A200

E94ASxE0594

EZS3-072A200

E94ASxE0864

E94AZRS0954

-

EZS3-115A200

150 m

300 m

2 kHz

or

4 kHz

E94ASxE1044

EZS3-150A200

E94ASxE1454

-

-

EZS3-180A200

150 m

- m

2 kHz

or

4 kHz

E94ASxE1724

-

-

EZS3-250A200

E94ASxE2024

-

-

EZS3-250A200

E94ASxE2454

-

-

EZS3-350A200

E94ASxE2924

-

-

EZS3-350A200

E94ASxE3664

-

-

EZS3-480A200

E94ASxE4604

-

-

EZS3-350A200

(2 in parallel)

E94ASxE5724

-

-

EZS3-480A200

(2 in parallel)

E94ASxE6354

-

-

EZS3-480A200

(2 in parallel)

E94ASxE6954

-

-

EZS3-350A200

(3 in parallel)

Tab. 4-3

EMC limit value class for conducted noise emission in TN/TT systems:

C2 to EN 61800-3 corresponds to class A to EN 55011

Advertising