1 operation at rated mains voltage 230 v, Operation at rated mains voltage 230 v, Regenerative power supply modules – Lenze 9400 Manual User Manual
Page 266: Input data (on the supply side)
Advertising
Regenerative power supply modules
Rated data (devices for 400/500V mains)
Operation at rated mains voltage 230 V
7
266
EDS94SPP101-7.1
7.3.1
Operation at rated mains voltage 230 V
Basis of the data
Mains
Voltage
Voltage range
Frequency range
U
LN
[V]
U
LN
[V]
f [Hz]
3/PE AC
230
180 - 0 % ... 264 + 0 %
45 ... 65
Input data (on the supply side)
Voltage
Frequency
Current [A]
Number of
phases
[V]
[Hz]
max. +45 °C c
max. +55 °C c
E94ARNE0134
In motor mode
230
50/60
26
19.5
3
In generator mode
230
50/60
13
9.8
3
E94ARNE0244
In motor mode
230
50/60
47
35
3
In generator mode
230
50/60
23.5
17.6
3
c
Temperature in the control cabinet
Voltage
Continuous input power
Type
[V]
S
L
[kVA]
E94ARNE0134
In motor mode
230
10.3
In generator mode
230
5.2
E94ARNE0244
In motor mode
230
18.7
In generator mode
230
9.4