Regenerative power supply modules

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 230 V

7

266

EDS94SPP101-7.1

7.3.1

Operation at rated mains voltage 230 V

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

230

180 - 0 % ... 264 + 0 %

45 ... 65

Input data (on the supply side)

Voltage

Frequency

Current [A]

Number of

phases

[V]

[Hz]

max. +45 °C c

max. +55 °C c

E94ARNE0134

In motor mode

230

50/60

26

19.5

3

In generator mode

230

50/60

13

9.8

3

E94ARNE0244

In motor mode

230

50/60

47

35

3

In generator mode

230

50/60

23.5

17.6

3

c

Temperature in the control cabinet

Voltage

Continuous input power

Type

[V]

S

L

[kVA]

E94ARNE0134

In motor mode

230

10.3

In generator mode

230

5.2

E94ARNE0244

In motor mode

230

18.7

In generator mode

230

9.4