4 operation at rated mains voltage 500 v, Operation at rated mains voltage 500 v, Single-axis controllers – Lenze 9400 Manual User Manual

Page 60: Device size 7

Advertising
background image

Single-axis controllers

Rated data (devices for 400/500V mains)

Operation at rated mains voltage 500 V

4

60

EDS94SPP101 EN 7.1

4.3.4

Operation at rated mains voltage 500 V

Device size 1 ... 6

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

2/PE DC

705

565 - 0 % ... 775 + 0 %

-

Mains current at I

aN

Output power

Motor power

(typical)

with external

mains choke

without external

mains choke

U, V, W

4 pol. ASM

Type

I

LN

[A]

I

LN

[A]

S

aN

[kVA]

P

aN

[kW]

P

aN

[hp]

E94ASxE0024

1.3

1.8

1.0

0.37

0.5

E94ASxE0034

2.2

3.1

1.7

0.75

1

E94ASxE0044

3.4

4.8

2.7

1.5

2

E94ASxE0074

6.1

8.7

4.8

3

4

E94ASxE0134

10.5

14.7

8.9

5.5

7.5

E94ASxE0174

13.1

18.4

11.3

7.5

10

E94ASxE0244

17.9

25.4

16.0

11

15

E94ASxE0324

-

26.0

21.8

15

20

E94ASxE0474

-

37.6

32.1

22

29

E94ASxE0594

-

47.0

40.2

30

40

Device size 7

Basis of the data
Mains

Voltage

Voltage range

Frequency range

U

LN

[V]

U

LN

[V]

f [Hz]

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

Mains current at I

aN

Output power

Motor power

(typical)

with external

mains choke

without external

mains choke

U, V, W

4 pol. ASM

Type

I

LN

[A]

I

LN

[A]

S

aN

[kVA]

P

aN

[kW]

P

aN

[hp]

E94AsxE0864

-

70.0

58.6

45

60

E94ASxE1044

-

84.0

70.9

55

73

Advertising